262 research outputs found

    Follicle Stimulating Hormone is an accurate predictor of azoospermia in childhood cancer survivors

    Get PDF
    Funding: RTM is supported by a Wellcome Trust Intermediate Clinical Fellowship (grant no: 098522), https://wellcome.ac.uk/what-we-do/directories/intermediate-clinical-fellowships-people-funded. TWK is supported by Engineering and Physical Sciences Research Council grant EP/P015638/1, http://gow.epsrc.ac.uk/NGBOViewGrant.aspx?GrantRef=EP/P015638/1.The accuracy of Follicle Stimulating Hormone as a predictor of azoospermia in adult survivors of childhood cancer is unclear, with conflicting results in the published literature. A systematic review and post hoc analysis of combined data (n = 367) were performed on all published studies containing extractable data on both serum Follicle Stimulating Hormone concentration and semen concentration in survivors of childhood cancer. PubMed and Medline databases were searched up to March 2017 by two blind investigators. Articles were included if they contained both serum FSH concentration and semen concentration, used World Health Organisation certified methods for semen analysis, and the study participants were all childhood cancer survivors. There was no evidence for either publication bias or heterogeneity for the five studies. For the combined data (n = 367) the optimal Follicle Stimulating Hormone threshold was 10.4 IU/L with specificity 81% (95% CI 76%–86%) and sensitivity 83% (95% CI 76%–89%). The AUC was 0.89 (95%CI 0.86–0.93). A range of threshold FSH values for the diagnosis of azoospermia with their associated sensitivities and specificities were calculated. This study provides strong supporting evidence for the use of serum Follicle Stimulating Hormone as a surrogate biomarker for azoospermia in adult males who have been treated for childhood cancer.Publisher PDFPeer reviewe

    Computers in the Exam Room: Differences in Physician–Patient Interaction May Be Due to Physician Experience

    Get PDF
    BACKGROUND: The use of electronic medical records can improve the technical quality of care, but requires a computer in the exam room. This could adversely affect interpersonal aspects of care, particularly when physicians are inexperienced users of exam room computers. OBJECTIVE: To determine whether physician experience modifies the impact of exam room computers on the physician–patient interaction. DESIGN: Cross-sectional surveys of patients and physicians. SETTING AND PARTICIPANTS: One hundred fifty five adults seen for scheduled visits by 11 faculty internists and 12 internal medicine residents in a VA primary care clinic. MEASUREMENTS: Physician and patient assessment of the effect of the computer on the clinical encounter. MAIN RESULTS: Patients seeing residents, compared to those seeing faculty, were more likely to agree that the computer adversely affected the amount of time the physician spent talking to (34% vs 15%, P = 0.01), looking at (45% vs 24%, P = 0.02), and examining them (32% vs 13%, P = 0.009). Moreover, they were more likely to agree that the computer made the visit feel less personal (20% vs 5%, P = 0.017). Few patients thought the computer interfered with their relationship with their physicians (8% vs 8%). Residents were more likely than faculty to report these same adverse effects, but these differences were smaller and not statistically significant. CONCLUSION: Patients seen by residents more often agreed that exam room computers decreased the amount of interpersonal contact. More research is needed to elucidate key tasks and behaviors that facilitate doctor–patient communication in such a setting

    Chirality of Matter Shows Up via Spin Excitations

    Full text link
    Right- and left-handed circularly polarized light interact differently with electronic charges in chiral materials. This asymmetry generates the natural circular dichroism and gyrotropy, also known as the optical activity. Here we demonstrate that optical activity is not a privilege of the electronic charge excitations but it can also emerge for the spin excitations in magnetic matter. The square-lattice antiferromagnet Ba2_2CoGe2_2O7_7 offers an ideal arena to test this idea, since it can be transformed to a chiral form by application of external magnetic fields. As a direct proof of the field-induced chiral state, we observed large optical activity when the light is in resonance with spin excitations at sub-terahertz frequencies. In addition, we found that the magnetochiral effect, the absorption difference for the light beams propagating parallel and anti-parallel to the applied magnetic field, has an exceptionally large amplitude close to 100%. All these features are ascribed to the magnetoelectric nature of spin excitations as they interact both with the electric and magnetic components of light

    Comparison of primary care experiences among adults in general outpatient clinics and private general practice clinics in Hong Kong

    Get PDF
    Abstract. Background. The main goal of Hong Kong's publicly-funded general outpatient clinics (GOPCs) is to provide primary medical services for the financially vulnerable. The objective of the current study was to compare the primary care experiences of GOPC users and the users of care provided by private general practitioners (GPs) in Hong Kong via a territory-wide telephone survey. Methods. One thousand adults in Hong Kong aged 18 and above were interviewed by a telephone survey. The modified Chinese translated Primary Care Assessment Tool was used to collect data on respondents' primary care experience. Results. Our results indicated that services provided by GOPC were more often used by female, older, poorer, chronically-ill and less educated population. GOPC participants were also more likely to have visited a specialist or used specialist services (69.7% vs. 52.0%; p < 0.001), although this difference in utilization of specialist services disappeared after adjusting for age (55.7% vs. 52.0%, p = 0.198). Analyses were also performed to asses the relationship between healthcare settings (GOPCs versus private GPs) and primary care quality. Private GP patients achieved higher overall PCAT scores largely due to better accessibility (Mean: 6.88 vs. 8.41, p < 0.001) and person-focused care (Mean: 8.37 vs. 11.69, p < 0.001). Conclusions. Our results showed that patients primarily receiving care from private GPs in Hong Kong reported better primary care experiences than those primarily receiving care from GOPCs. This was largely due to the greater accessibility and better interpersonal relationships offered by the private GPs. As most patients use both GOPCs and private GPs, their overall primary care experiences may not be as different as the findings of this study imply. Š 2010 Wong et al; licensee BioMed Central Ltd.link_to_subscribed_fulltex

    Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV

    Get PDF
    The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pT≥20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60≤pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≤{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration

    Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector

    Get PDF
    The inclusive and dijet production cross-sections have been measured for jets containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The measurements use data corresponding to an integrated luminosity of 34 pb^-1. The b-jets are identified using either a lifetime-based method, where secondary decay vertices of b-hadrons in jets are reconstructed using information from the tracking detectors, or a muon-based method where the presence of a muon is used to identify semileptonic decays of b-hadrons inside jets. The inclusive b-jet cross-section is measured as a function of transverse momentum in the range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet cross-section is measured as a function of the dijet invariant mass in the range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets and the angular variable chi in two dijet mass regions. The results are compared with next-to-leading-order QCD predictions. Good agreement is observed between the measured cross-sections and the predictions obtained using POWHEG + Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet cross-section. However, it does not reproduce the measured inclusive cross-section well, particularly for central b-jets with large transverse momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final version published in European Physical Journal

    Assessing and reporting heterogeneity in treatment effects in clinical trials: a proposal

    Get PDF
    Mounting evidence suggests that there is frequently considerable variation in the risk of the outcome of interest in clinical trial populations. These differences in risk will often cause clinically important heterogeneity in treatment effects (HTE) across the trial population, such that the balance between treatment risks and benefits may differ substantially between large identifiable patient subgroups; the "average" benefit observed in the summary result may even be non-representative of the treatment effect for a typical patient in the trial. Conventional subgroup analyses, which examine whether specific patient characteristics modify the effects of treatment, are usually unable to detect even large variations in treatment benefit (and harm) across risk groups because they do not account for the fact that patients have multiple characteristics simultaneously that affect the likelihood of treatment benefit. Based upon recent evidence on optimal statistical approaches to assessing HTE, we propose a framework that prioritizes the analysis and reporting of multivariate risk-based HTE and suggests that other subgroup analyses should be explicitly labeled either as primary subgroup analyses (well-motivated by prior evidence and intended to produce clinically actionable results) or secondary (exploratory) subgroup analyses (performed to inform future research). A standardized and transparent approach to HTE assessment and reporting could substantially improve clinical trial utility and interpretability

    Self-care and adherence to medication: a survey in the hypertension outpatient clinic

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Self-care practices for patients with hypertension include adherence to medication, use of blood pressure self-monitoring and use of complementary and alternative therapies (CAM) The prevalence of CAM use and blood pressure self-monitoring have not been described in a UK secondary care population of patients with hypertension and their impact on adherence to medication has not been described. Adherence to medication is important for blood pressure control, but poor adherence is common. The study aimed to determine the prevalence of self-care behaviours in patients attending a secondary care hypertension clinic.</p> <p>Methods</p> <p>Cross-sectional questionnaire survey. 196 patients attending a secondary care hypertension clinic in a teaching hospital serving a multiethnic population, Birmingham, UK. Main outcome measures: Prevalence of use of CAM, home monitors, adherence to anti-hypertensive medication.</p> <p>Results</p> <p>CAM use in previous 12 months was reported by 66 (43.1%) respondents. CAM users did not differ statistically from non-CAM users by age, gender, marital status or education. Vitamins, prayer a dietary supplements were the most commonly used CAM. Nine (12.7%) women reported using herbal CAM compared to one man (1.2%), (p = 0.006). Ten (6.7%) respondents reported ever being asked by a doctor about CAM use. Perfect adherence to anti-hypertensive medication was reported by 26 (44.8%) CAM-users and 46 (60.5%) non-CAM users (p = 0.07). Being female and a CAM user was significantly associated with imperfect adherence to anti-hypertensive medication. Older and white British respondents were significantly more likely to report perfect adherence. Blood pressure monitors were used by 67 (43.8%) respondents, which was not associated with gender, CAM use or adherence to medication.</p> <p>Conclusion</p> <p>Hypertensive patients use a variety of self-care methods, including CAM, home blood pressure monitors, and adherence to prescribed medication. This study found the prevalence of CAM use in hypertensive patients was higher than in the UK population. It is important to acknowledge the self-care behaviour of hypertensive patients, in order to assess potential harm, and encourage effective methods of self-care.</p
    • …
    corecore